Summary

This report outlines the findings of our height safety compliance audit conducted at 2 Markham Place, Ashfield NSW 2131.

The assessment has been carried out in accordance with the relevant Australian Standards and Safe Work Australia guidance to determine the most appropriate and compliant access solution for the maintenance access to the rainwater tank mezzanine area.

Audit Type

Height Safety Compliance Assessment

Site Address

2 Markham Place, Ashfield NSW 2131

Standards Assessed

AS 1657:2018, NCC/BCA Volume One, Safe Work Australia Guidelines

Outcome

Compliant Access Solution Identified

Audit Highlights

Site Inspection

Detailed on-site inspection of existing conditions and access constraints.

Risk Assessment

Assessment of current access arrangements and associated risks.

Compliance Review

Review against applicable standards and regulatory requirements.

Access Solution

Identification of the most suitable compliant access solution for the site.

Recommendations

Practical recommendations for implementation and ongoing compliance.

Our Commitment

ASG is committed to delivering safe, practical and compliant access solutions that protect people, assets and reputations.

Delivering Safety. Ensuring Compliance. Building Trust.

Why Choose ASG

Trusted by Australia's Best

For nearly two decades, we've been the go-to team for some of Australia's most iconic properties and biggest names. When safety matters, they call us.

Trusted Since 2007

13 Years Servicing Kirribilli House

We've proudly maintained the Prime Minister's official Sydney residence for over 13 years — a testament to the trust placed in our team for the highest standards of safety, discretion, and quality.

Proudly partnering with leading organisations across Australia

Mirvac
Commonwealth Bank
Macquarie Bank
John Holland
CBRE
JLL
Charter Hall
Sydney Airport
TOGA
Built
Buildcorp
Horizon Power
Strata Choice
Supercheap Auto
18+
Years Experience
500+
Projects Completed
100%
Safety Record
24/7
Emergency Response

We're real people who genuinely care about keeping your team safe. No jargon, no runaround — just honest advice and quality work you can count on.

1

Executive Summary

ASG was engaged by Propel Property Advisory (Chris Stanley, Project Director) to conduct a height safety access compliance audit of the existing maintenance access arrangement at 2 Markham Place, Ashfield NSW 2131. The mezzanine houses fire and plumbing pump systems requiring routine maintenance access.

Critical Finding

The existing access arrangement relies entirely on an unsecured portable ladder with no restraint system, no landing platform, no guardrails, and no defined safe access route. This arrangement presents an unacceptable fall risk and does not comply with AS 1657:2018, NCC/BCA Volume One, or the Safe Work Australia Model Code of Practice for Managing the Risk of Falls at Workplaces.

0
Non-Compliances
0
High Risk Items
0
Medium Risk Items
0
Compliant Items

Compliance Alignment

AS 1657:2018Fixed Platforms, Walkways, Stairways and Ladders
ALIGNED
NCC/BCA Volume OnePart D3 — Access & Egress; Part G8 — Maintenance Access
ALIGNED
Safe Work AustraliaModel Code of Practice: Managing the Risk of Falls at Workplaces
ALIGNED
SafeWork NSWPocket Guide to Ladder Safety; Portable Ladder Fact Sheet
ALIGNED
2

Site Overview

Site photograph
Figure 2.0 — Mezzanine level, structural beam, concrete upturn wall, and driveway below
Architectural plan
Figure 2.1 — Architectural markup plan showing mezzanine, rainwater tanks, access point

The subject area comprises a raised mezzanine platform housing four 5,000-litre rainwater tanks, a filtration chamber, and an overflow chamber. The mezzanine is bounded by an H1200 concrete upturn wall (W250) along the driveway edge, with the finished floor level (FFL) at approximately RL +28.200.

Mezzanine FFL
RL +28.200
Upturn Wall
H1200 × W250
Rainwater Storage
4 × 5,000L
Adjacent Area
Driveway Zone
Access (Existing)
Portable Ladder
Key Constraint
Vehicle Traffic
3

Existing Condition Audit

A detailed audit identified ten critical non-compliant conditions, each representing a significant safety deficiency requiring immediate remediation.

1
No permanent access systemHIGH

Absence of fixed or engineered access for routine maintenance

AS 1657:2018 Cl. 3.1; NCC Part G8

2
Reliance on portable ladderHIGH

Portable ladders not suitable as primary access for repeated maintenance

SWA Falls CoP Cl. 3.4; SafeWork NSW

3
No ladder restraintHIGH

Ladder not secured; risk of lateral displacement or base slip

AS 1657:2018 Cl. 7.4; SWA CoP Cl. 4.7

4
No landing platformHIGH

No safe stepping-off point; uncontrolled transition at height

AS 1657:2018 Cl. 5.3, Cl. 7.5

5
No guardrails at edgeHIGH

Unprotected edge; fall hazard from mezzanine level

AS 1657:2018 Cl. 6; NCC D3D17

6
Unsafe wall transitionHIGH

Personnel must climb over H1200 wall with no handholds

AS 1657:2018 Cl. 5.3; SWA CoP Cl. 3.2

7
No defined access routeMEDIUM

No designated path from ground to mezzanine

NCC Part D1; AS 1657:2018 Cl. 3.1

8
Vehicle interaction exposureHIGH

Access point within active driveway; no separation

SWA CoP Cl. 3.1; WHS Reg. 2017 Cl. 35

9
Lack of signageMEDIUM

No warning, directional, or access control signage

AS 1657:2018 Cl. 10; WHS Reg. Cl. 36

10
No controlled access methodologyMEDIUM

No documented procedure, permit, or access control

SWA CoP Cl. 3.3; AS 1657:2018 Cl. 3.2

ASG in Action

Delivering Safety Solutions Across Australia

Rope Access
Rope Access
Height Safety Install
Height Safety Install
ASG Team
ASG Team
Commercial Projects
Commercial Projects
4

Proposed Access Solution

ASG has developed a bespoke engineered access solution comprising seven integrated components, specifically designed for this site's constrained geometry.

1

Angled Offset Support Bracket

Aluminium bracket mounted to wall top; offsets ladder ~10° RHS to reduce driveway encroachment

AS 1657:2018 Cl. 7.4

2

Ladder Stabiliser Bracket

Receives and restrains the top of the portable ladder; prevents lateral displacement

AS 1657:2018 Cl. 7.4; SWA CoP

3

Portable Extension Ladder

Standard industrial extension ladder engaged into stabiliser bracket for ascent/descent

AS/NZS 1892.1; SafeWork NSW

4

500mm Landing/Rest Platform

Provides safe stepping-off point at top of portable ladder; rest area during transition

AS 1657:2018 Cl. 5.3

5

Guardrail System

Top rail (1000mm), mid rail, and toe board providing edge protection at platform

AS 1657:2018 Cl. 6; NCC D3D17

6

Fixed 4-Rung Transition Ladder

Vertical ladder hard against inside face of wall; controlled descent to mezzanine (~1m)

AS 1657:2018 Cl. 7.2

7

Handrail Arrangement

Continuous handrails at platform and transition ladder for three-point contact

AS 1657:2018 Cl. 6.4

Ladder Offset Angle
~10° RHS
Platform Size
500 × 500 mm
Guardrail Height
1000 mm
Transition Ladder
4 Rungs, Vertical
Ladder Inclination
75° (portable)
Wall Height
1200 mm

Critical Design Note

The fixed 4-rung transition ladder on the mezzanine side is a vertical ladder mounted hard against the inside face of the concrete upturn wall. It provides approximately 1m of descent from the platform level to the mezzanine FFL. This is not an angled ladder — it is a vertical fixed ladder with handrails, complying with AS 1657:2018 Clause 7.2 for vertical fixed ladders less than 6m in height.

5

Compliance & Standards

Hierarchy of Controls — Falls Prevention

1
ELIMINATE
Not practicable
2
ENGINEERING CONTROLS
PROPOSED ←
3
ADMINISTRATIVE CONTROLS
Supplementary
4
PPE
Last resort
5
EXISTING
CURRENT ←

Applicable Legislation & Standards

WHS Act 2011 (NSW)
Primary Duty of Care — PCBU obligations
WHS Regulation 2017
Division 8 — Managing risks of falls
AS 1657:2018
Fixed Platforms, Walkways, Stairways & Ladders
NCC/BCA 2022
Parts D1, D3, G8 — Access & Maintenance
SWA Model Code of Practice
Managing the Risk of Falls at Workplaces
SafeWork NSW
Ladder Safety Guidance & Fact Sheets

Recommendation

ASG recommends the immediate implementation of the proposed access solution to eliminate the identified fall hazards, achieve compliance with applicable Australian Standards and WHS legislation, and establish a safe, controlled, and repeatable access methodology for ongoing maintenance of the rainwater tank mezzanine area.

Your Partner in Safety
ASG

Your Partner
in Safety

Specialist height safety, rope access, and building maintenance solutions across Australia.

What We Do

Our Core Services

Height Safety Systems

Height Safety Systems

Design, installation, and certification of anchor points, static lines, guardrails, and access platforms to Australian Standards.

Rope Access Services

Rope Access Services

IRATA-certified rope access for building maintenance, inspections, painting, and installations at any height.

Compliance Audits

Compliance Audits

Comprehensive height safety compliance assessments against AS 1657:2018, NCC/BCA, and WHS legislation.

Our Work

Projects & Team

Ready to Get Started?

Contact ASG to discuss this proposal, schedule an on-site consultation, or learn more about our height safety solutions.

Learn More

Explore ASG Australia

Browse our full website below or open in a new tab

ADVANCEDSOLUTIONS
Advanced Solutions Group Pty Ltd
Prepared for Propel Property Advisory | 2 Markham Pl, Ashfield NSW | Rev A — 14 May 2026 | Confidential